Accendo Reliability

Your Reliability Engineering Professional Development Site

  • Home
  • About
    • Contributors
  • Reliability.fm
    • Speaking Of Reliability
    • Rooted in Reliability: The Plant Performance Podcast
    • Quality during Design
    • Way of the Quality Warrior
    • Critical Talks
    • Dare to Know
    • Maintenance Disrupted
    • Metal Conversations
    • The Leadership Connection
    • Practical Reliability Podcast
    • Reliability Matters
    • Reliability it Matters
    • Maintenance Mavericks Podcast
    • Women in Maintenance
    • Accendo Reliability Webinar Series
  • Articles
    • CRE Preparation Notes
    • on Leadership & Career
      • Advanced Engineering Culture
      • Engineering Leadership
      • Managing in the 2000s
      • Product Development and Process Improvement
    • on Maintenance Reliability
      • Aasan Asset Management
      • AI & Predictive Maintenance
      • Asset Management in the Mining Industry
      • CMMS and Reliability
      • Conscious Asset
      • EAM & CMMS
      • Everyday RCM
      • History of Maintenance Management
      • Life Cycle Asset Management
      • Maintenance and Reliability
      • Maintenance Management
      • Plant Maintenance
      • Process Plant Reliability Engineering
      • ReliabilityXperience
      • RCM Blitz®
      • Rob’s Reliability Project
      • The Intelligent Transformer Blog
      • The People Side of Maintenance
      • The Reliability Mindset
    • on Product Reliability
      • Accelerated Reliability
      • Achieving the Benefits of Reliability
      • Apex Ridge
      • Metals Engineering and Product Reliability
      • Musings on Reliability and Maintenance Topics
      • Product Validation
      • Reliability Engineering Insights
      • Reliability in Emerging Technology
    • on Risk & Safety
      • CERM® Risk Insights
      • Equipment Risk and Reliability in Downhole Applications
      • Operational Risk Process Safety
    • on Systems Thinking
      • Communicating with FINESSE
      • The RCA
    • on Tools & Techniques
      • Big Data & Analytics
      • Experimental Design for NPD
      • Innovative Thinking in Reliability and Durability
      • Inside and Beyond HALT
      • Inside FMEA
      • Integral Concepts
      • Learning from Failures
      • Progress in Field Reliability?
      • R for Engineering
      • Reliability Engineering Using Python
      • Reliability Reflections
      • Testing 1 2 3
      • The Manufacturing Academy
  • eBooks
  • Resources
    • Accendo Authors
    • FMEA Resources
    • Feed Forward Publications
    • Openings
    • Books
    • Webinars
    • Journals
    • Higher Education
    • Podcasts
  • Courses
    • 14 Ways to Acquire Reliability Engineering Knowledge
    • Reliability Analysis Methods online course
    • Measurement System Assessment
    • SPC-Process Capability Course
    • Design of Experiments
    • Foundations of RCM online course
    • Quality during Design Journey
    • Reliability Engineering Statistics
    • Quality Engineering Statistics
    • An Introduction to Reliability Engineering
    • Reliability Engineering for Heavy Industry
    • An Introduction to Quality Engineering
    • Process Capability Analysis course
    • Root Cause Analysis and the 8D Corrective Action Process course
    • Return on Investment online course
    • CRE Preparation Online Course
    • Quondam Courses
  • Webinars
    • Upcoming Live Events
  • Calendar
    • Call for Papers Listing
    • Upcoming Webinars
    • Webinar Calendar
  • Login
    • Member Home

by Mike Sondalini Leave a Comment

Extreme Wear on the Back Plate of Centrifugal Pumps

Extreme Wear on the Back Plate of Centrifugal Pumps

Why is extreme wear occurring on the backing plate behind the impellers of these centrifugal pumps used for irrigation pumping service?

Engineering investigations into the causes of wear, erosion and metal loss on the back-plates behind the impellers of two year old centrifugal pumps pumping water about an irrigation system

Hello Mike,

We have just commenced our winter maintenance schedule in the irrigation water pump stations and have found some serious wear issues occurring behind the pump impellers. I have reviewed documentation on pump cavitation and cannot see anything that looks similar to what we are seeing on our pumps. Photos of the problem are in this PDF document of the typical condition of centrifugal pump back-plates. There is very little wear occurring on the brass impellers, the volutes or on impeller vanes, however, we are seeing extreme gouging and wear to the cast backing plates on the motor side of the impellers. Are you able to shed some light on this ?

Hello John,

The badly affected outer annulus showing on the back plate under the wear ring end is most likely due to high differential pressures between the discharge and suction sides of the impeller. The balance holes in the impeller are at the low suction pressure of the impeller inlet. Water will always flow from the high pressure discharge side of the impeller and past the wear ring then out through the balance holes back to the low pressure suction. The wearing ring combines with the backing plate, impeller wall and shaft to form a chamber and water will swirl about the chamber at faster and faster speeds as the differential pressure between discharge and suction rises. Recirculation erosion and cavitation are both definitely possible, especially at low pump flow conditions.

If the gap between the backing plate and the end of the wear ring is small (say less than 2-3mm) I would expect erosion from high liquid velocity as well as cavitation when a pressure differential causes recirculating water in no flow and low flow situations. It would be worth measuring the distance of the gap between the back plate and the end of the wear ring. The fact that there is a concave scallop on the end of the wear ring supports a high liquid velocity cause.

I would also expect to see evidence of wear/erosion on the back plate wear ring surface where the impeller wear ring runs inside it due to high water velocities. Please also check the clearance distance between the impeller wear ring and the back plate wear ring sealing surfaces to see what they are when the pump is assembled. The gap needs to be tight—around 0.1 mm. If there is more than 0.1mm gap there will be a great amount of recirculation during dead-head and low flow events. Also look with a magnifying glass at the back plate wearing ring surface for signs of erosion or preferential tracking from high pressure to low pressure.

The deeply affected annulus around the shaft looks like erosion. It is likely that localised eddy flows swirl in the chamber corner around the shaft as the water moves from high pressure at the wear ring to low pressure at the balance holes. If the shaft is made of stainless steel then preferential galvanic corrosion of the cast iron becomes another contributing possibility.

Since the irrigation pumps pressurise to 650kPag and maintain that pressure in a water distribution system there will always be high pressure on the discharge side of the impeller. If you run the pumps against that pressure you will always create recirculation across the wear ring and get the wear patterns seen in the back plate. To stop the back plate erosion and/or cavitation you must stop running as many pumps as possible when there is little or no flow in the distribution system. You only want to run a pump when there is draw-off from the distribution piping.

If there is a galvanic problem present as well, regulating the flow characteristics will not change that failure mode. Next year sample a pump from each station and strip it down as you have done in the current refurbishment. If there is still damage to the back plate after making process control modifications to prevent pumping at no flow and low flow conditions then galvanic problems are a real possibility.

I would also send the photos of the pump wear to the pump OEM design engineers and get them to make a determination of the possible causes of the problem. They designed the pump and will know the likely causes of such problems.

Ask the OEM for replacement back plates with better wear and cavitation resistant properties.

You may still have another problem. This one is financial. If you keep the pump configuration as is, then potentially every two years you will spend something like $2,000 (for parts and labour) on every pump in your system to refurbish it with a new back plate. Over the life of the pumps it will total to a lot of money. You might want to think about using alternate materials in future (both galvanically compatible and harder wearing against erosion) if next years inspection shows that a problem is still present.

My best regards to you,

Mike Sondalini
Managing Director
Lifetime Reliability Solutions HQ

Filed Under: Articles, on Maintenance Reliability, Plant Maintenance

About Mike Sondalini

In engineering and maintenance since 1974, Mike’s career extends across original equipment manufacturing, beverage processing and packaging, steel fabrication, chemical processing and manufacturing, quality management, project management, enterprise asset management, plant and equipment maintenance, and maintenance training. His specialty is helping companies build highly effective operational risk management processes, develop enterprise asset management systems for ultra-high reliable assets, and instil the precision maintenance skills needed for world class equipment reliability.

« 3 Ways to Do RCM
Sell Solutions Before There’s a Problem »

Leave a Reply Cancel reply

Your email address will not be published. Required fields are marked *

Article by
Mike Sondalini
in the
Plant Maintenance series articles provided courtesy of Feed Forward Publications and Lifetime Reliability Solutions.

Join Accendo

Receive information and updates about articles and many other resources offered by Accendo Reliability by becoming a member.

It’s free and only takes a minute.

Join Today

Recent Articles

  • test
  • test
  • test
  • Your Most Important Business Equation
  • Your Suppliers Can Be a Risk to Your Project

© 2025 FMS Reliability · Privacy Policy · Terms of Service · Cookies Policy